Fabrication Services — Vessel Fabrication
Slug Catchers
Finger-type and vessel-type slug catchers engineered to absorb sudden surges of liquid arriving from multiphase pipelines — protecting downstream separation and processing equipment from overload and shutdown.
Buffering the pipeline’s worst moment, not just its average flow
Multiphase gas-liquid pipelines rarely deliver a steady, predictable mixture to the receiving facility. Terrain changes, pipeline pigging operations, and ordinary hydrodynamic instability inside the line all generate slugs — large surges of liquid that can arrive many times larger than the pipeline’s average liquid holdup. A slug catcher is the static equipment, in vessel or piping-network form, sized to absorb the largest anticipated slug and release it to downstream separation and storage at a controlled, metered rate.
Fintelius sizes every slug catcher against transient pipeline simulation — terrain-induced slugging, pigging ramp-up volumes, and worst-case operating scenarios — before selecting a finger-type, vessel-type, or hybrid configuration to match the volume, pressure, and plot-space constraints of the site.
- Finger-type (harp/multi-pipe) and vessel-type (horizontal/vertical two-phase separator) configurations
- Sized against transient slug-volume simulation, pigging frequency, and ramp-up rate
- Carbon steel manifolds as standard, corrosion-resistant alloys for sour CO₂/H₂S service
- Fabricated to ASME B31.8 / B31.3 and CSA Z662, with 200-micron minimum separation performance
Three sources of slugging, one design response
A slug catcher has to be sized for the worst credible combination of these mechanisms, not just steady-state flow.
Terrain-Induced Slugging
Liquid accumulates in low points along an undulating pipeline profile and is periodically swept forward in large surges as gas velocity builds.
Pigging-Induced Slugging
A pipeline pig sweeps accumulated liquid ahead of it, delivering the pipeline’s entire liquid inventory as a single large slug on arrival.
Hydrodynamic (Operational) Slugging
Normal multiphase flow instability generates slugs continuously during steady operation, at a scale the slug catcher must absorb without upset.
From transient simulation to a commissioned slug catcher
Every unit follows the same disciplined path through design and fabrication, whatever its configuration.
Transient Simulation & Sizing
Pipeline profile, pigging frequency, and ramp-up rate are modeled to estimate the largest anticipated slug volume.
Configuration Selection
Finger-type, vessel-type, or hybrid design is selected against required volume, pressure rating, and available plot space.
Manifold & Vessel Fabrication
Large-diameter pipe manifolds or separator shells are rolled, welded, and fitted with gas risers, equalization lines, and internals.
Welding, NDE & PWHT
All welds are radiographed and ultrasonically tested; thick sections undergo post-weld heat treatment where required.
Hydrostatic Testing & Dispatch
The complete unit is hydrostatically tested, coated, and prepared for shipment as a skid or in sections for field erection.
Matched to volume, pressure & plot space
Vessel-Type
A horizontal or vertical two-phase separation vessel — vertical configurations offer the highest separation efficiency, most economical for slug volumes under roughly 100 m³.
Finger-Type (Harp)
Large-diameter pipes arranged in parallel “fingers,” each with a gas/liquid separation section, an intermediate zone, and dedicated storage volume — the economical choice for high-pressure, high-volume applications.
Hybrid & Parking-Loop
Combines the separation efficiency of a vessel-type unit with the large storage capacity of a finger-type harp — a compromise configuration where both efficiency and volume matter.
What makes a finger-type slug catcher reliable
Small design decisions compound into large differences in flooding behavior, foundation cost, and installed footprint.
Even Finger Count
An even number of parallel fingers balances flow distribution — odd counts commonly cause uneven loading and localized flooding in individual fingers.
Flow-Driven Sizing
Finger count and diameter are set from gas flow rate (actual cubic feet per second), with finger length then sized to the required storage volume.
Low-Slope Manifold Layout
Modern finger-type layouts can achieve roughly a 1:100 slope versus the 7:100 slope of older stratified designs — substantially reducing installation height and foundation cost.
Inlet Distribution Piping
Adequate straight-run inlet piping (on the order of 5 pipe diameters) promotes stratified flow entering the manifold for even distribution across fingers.
Gas Risers & Equalization Lines
Riser and equalization piping balance gas pressure across all fingers, preventing one finger from over- or under-filling relative to the others.
Materials for Sour Service
High-strength carbon steel manifolds (to MSS-SP-75) suit non-corrosive streams; corrosion-resistant alloys are specified where CO₂ or H₂S content demands it.
Built for reliable oil-water-gas segregation
Fixed Weir Storage Arrangement
Slug storage volume held between normal and high liquid level switches, with a weir maintaining predictable oil-water segregation.
Inverted-Harp Storage Fingers
Modular finger arrangements allow additional storage fingers to be added later without downtime or interruption to production.
Oil Bucket Spillover Lip
Prevents oil-phase overflow into the water draw section during high-level operation.
Underflow Mitigation
Restricts oil carryover into water-draw piping, protecting downstream water treatment systems from hydrocarbon contamination.
Pigging Launcher/Receiver Integration
Manifold inlet design accommodates pig arrival directly ahead of the slug catcher, managing the pipeline’s full liquid inventory on pig passage.
Radiography & Hydrostatic Test
Weld integrity verification and full-pressure hydrostatic testing prior to dispatch, per the governing piping or vessel code.
Capability at a glance
Where our slug catchers go to work
Production Facilities
Buffering multiphase flowline slugging at the wellhead or gathering manifold ahead of primary separation.
Midstream Infrastructure
Protecting gathering and transmission pipeline receiving facilities from pigging and terrain-induced slug arrivals.
Refinery & Downstream Operations
Managing feedstock slugging ahead of downstream process units to prevent overload and unplanned shutdown.
Long-Distance Pipelines
Absorbing slug volumes generated by elevation changes along pipeline routes with fluctuating terrain profiles.
Gas Processing Plants
Stabilizing inlet flow ahead of dehydration, dew point control, and compression equipment.
Pigging Operations
Receiving the full pipeline liquid inventory swept ahead of a pig without upsetting downstream processing.