Fabrication Services — Vessel Fabrication
Custom Mud Gas Separators
Open-bottom, closed-bottom, and float-type mud gas separators — “poor boy” degassers built to strip free gas from drilling fluid returns during a well-control kick, venting it safely away from rig personnel and equipment.
The last line of defense before gas reaches the shaker
A mud gas separator — universally known on the rig floor as a “poor boy” degasser — is a vertical vessel installed in the mud return line to strip free gas out of drilling fluid before it reaches the shale shakers and mud tanks. It’s called into service specifically during well-control events: when the mud column is temporarily underbalanced and a kick brings gas-cut mud up the annulus, the separator vents that gas safely to the flare line while returning degassed mud to the active system.
Fintelius fabricates every separator around the two numbers that actually keep a rig crew safe: the liquid-seal (mud leg) height that holds back pressure against the incoming gas, and the vent-line capacity that carries that gas away without building dangerous backpressure. Both are engineered before a single plate is rolled.
- Open-bottom (classic “poor boy”), closed-bottom, and float-type configurations
- Sized to API 12J & ASME Section VIII Div. 1, capacity rated in gallons per minute at the inlet
- Minimum 10-ft liquid-seal (mud leg) height engineered against expected back pressure
- Oversized, valve-free vent lines routed to flare, sized independently for oil and gas service
From well-control criteria to a hydrostatically tested vessel
Every separator follows the same disciplined path through the shop, whatever configuration is specified.
Well-Control Sizing
Expected gas rate, mud weight, and maximum anticipated back pressure size the vessel diameter, height, and mud-leg length.
Configuration Selection
Open-bottom, closed-bottom, or float-type outlet is selected against rig layout and mud-return routing requirements.
Shell & Baffle Fabrication
Vessel shell is rolled and fitted with spiral cascade baffles and erosion-protection plates at the inlet impingement zone.
Welding, NDE & PWHT
All welds are radiographed and ultrasonically tested; sections are heat-treated where code requires.
Hydrostatic Testing & Dispatch
The complete vessel is hydrostatically tested well above working pressure, coated, and prepared for rig-site shipment.
Matched to rig layout & mud-return routing
Open-Bottom (“Poor Boy”)
The classic configuration — the vessel base sits immersed in the mud tank, using the surrounding mud itself to form the liquid seal against gas escape.
Closed-Bottom
A sealed base routes degassed mud through a dedicated return line to the tank — used where the vessel cannot be mounted directly over an open tank.
Float-Type
A float-actuated valve replaces the permanent liquid seal, mounted on a fixed or elevated pedestal — suited to rig layouts needing a controlled, valved mud return.
The numbers that determine whether the separator holds
A poor boy degasser fails dangerously, not gracefully — these parameters are engineered with margin, not estimated.
Liquid Seal (Mud Leg) Height
A minimum 10-ft mud leg provides roughly 5 psi of back pressure at typical drilling fluid density — the barrier that keeps gas from blowing through into the shaker header.
Vent Line Sizing
Oil-service vent lines run 8 in. minimum OD; gas-service lines are diverted into dual 8 in. lines at ground level, oversized specifically to minimize backpressure.
Vent Line Routing
Lines run a minimum of 100 ft beyond the far edge of the reserve pit, with no valves permitted anywhere in the run to the flare.
Inlet Sizing
Inlet diameter matches the largest choke manifold line in service, typically 4 in. ID or larger, to avoid restricting flow during a kick.
Internal Cascade Baffles
Spiral, half-diameter baffle plates force mud through a longer path, encouraging gas to break out before the mud reaches the outlet.
Erosion Protection
Impingement plates protect the vessel wall at the point where high-velocity, sand-laden mud strikes the shell.
What a well-control vessel demands
Shell & Head Fabrication
Rolled shell and formed heads to a minimum 48 in. diameter and 16 ft height for standard rig applications.
Outlet Line Sizing
8 in. minimum mud outlet, 12 in. recommended where returns carry high-viscosity or heavily contaminated fluid.
Nozzle & Flange Fabrication
Inlet, vent, mud outlet, and instrumentation nozzles fitted to match choke manifold and flare-line connection standards.
By-Pass Line to Flare
A dedicated by-pass line to the flare stack as a safety precaution, independent of the primary vent path.
Sour Service (H₂S) Construction
Materials and seals rated for hydrogen sulfide exposure where drilling fluid carries elevated H₂S concentrations.
Post-Weld Heat Treatment
Stress-relief heat treatment for thick-walled sections per ASME code requirements.
Radiography & Ultrasonic NDE
Weld integrity verification across shell, head, and nozzle welds before hydrostatic test.
Hydrostatic Testing
Tested to roughly 190 psi for a typical 150 psi maximum working pressure rating.
Pressure Gauge & Monitoring
Pressure instrumentation to monitor back pressure against mud-leg hydrostatic head and warn of blow-through risk.
Capability at a glance
Where our mud gas separators go to work
Well Control & Kick Handling
Primary duty — venting gas-cut mud safely to the flare during a kick while returning usable mud to the active system.
Deep Gas Drilling
High-capacity separators for wells with significant anticipated gas volumes and elevated formation pressures.
Sour Gas Drilling
H₂S-rated construction for drilling fluid returns carrying elevated hydrogen sulfide concentrations.
Underbalanced Mud Operations
Protecting rig crews and equipment when the mud column runs intentionally or unintentionally underbalanced against formation pressure.
Land & Offshore Rigs
Configurations adapted for both onshore drilling packages and offshore platform installations.
General Excavation Operations
Gas separation duty extending beyond drilling into broader excavation and subsurface work.