Fabrication Services — Heat Exchanger Fabrication
Air Cooled Heat Exchangers & Fin Fan Coolers
Engineered and shop-fabricated air cooled heat exchangers — induced and forced draft units, every header and fin-tube configuration, built to API 661, ASME Section VIII Div. 1 & TEMA for refineries, gas processing, petrochemical, and power plants.
Process cooling wherever water is scarce, costly, or unavailable
An air cooled heat exchanger (ACHE) — widely known as a fin fan cooler — rejects process heat directly to ambient air instead of cooling water, using banks of finned tube bundles and axial fans mounted on a structural steel bay. Fintelius engineers, fabricates, and tests complete ACHE units and replacement tube bundles for gas compression, gas processing, refining, and power applications.
Every bundle is engineered around the process duty — fluid, pressure, temperature approach, and site ambient conditions — then matched to the header type, fin technology, and draft arrangement that fits the application, and shop-tested before dispatch.
- Induced & forced draft units in horizontal, A-frame & vertical arrangements
- Plug, cover-plate, welded bonnet, manifold & pipe header designs
- Embedded (G-fin), extruded, L-foot, LL-foot & KLM finned tube technology
- Engineered, fabricated & tested to API 661, ASME Section VIII Div. 1 & TEMA
From process data to a shop-tested bundle
Every ACHE unit or replacement bundle follows the same disciplined engineering-to-dispatch path.
Thermal & Mechanical Design
Process conditions and site ambient data are used to size bundle face area, tube length, fin type, and fan duty.
Header & Tube Fabrication
Headers are welded or bolted per the selected design and finned tubes are rolled or expanded into the tubesheet.
Bundle Assembly
Tube bundles are assembled, framed, and mounted into the structural steel bay with plenum and louvers.
Fan & Drive Integration
Axial fans, fan rings, drive assemblies, and motors are installed and aligned for the specified draft arrangement.
Testing & Dispatch
Hydrostatic testing, NDE, and a mechanical running test are performed before the unit is prepared for shipment.
Forced draft, induced draft & A-frame arrangements
Draft type and bundle arrangement are selected for plot space, noise, and process requirements.
Forced Draft
Fans mounted below the bundle push air upward through the tubes — simple fan and drive access for maintenance, and effective in higher ambient temperatures.
Induced Draft
Fans mounted above the bundle pull air through the tubes for a more even air distribution across the face area, with a plenum shielding the bundle from solar radiation and weather.
A-Frame & Vertical
Angled or vertical bundle arrangements reduce plot footprint where site space is restricted, typically paired with forced draft fans.
Header type matched to design pressure
Header selection is driven by the bundle’s design pressure and cleaning/maintenance requirements.
Plug Header
Fully welded box header with removable plugs opposite each tube end for mechanical cleaning — suited to high-pressure, high-temperature service.
Cover Plate Header
Removable cover plate provides full-face access to all tube ends for inspection and cleaning at moderate design pressures.
Welded Bonnet Header
Fully welded bonnet box for clean, non-fouling services where tube-end access is not required in operation.
Manifold Header
Pipe manifold construction distributing flow across multiple tube rows, typical of smaller or lower-pressure bundles.
Pipe Header
Pipe-and-bend header construction for simple, economical bundle designs.
D-Header / Bonnet Type
D-shaped bonnet header configuration used for specific tube-pass and flow-distribution requirements.
Fin type sized to the operating temperature
Fin construction is selected primarily on maximum tube-wall operating temperature and fouling environment.
L-Foot Fin
Aluminum strip wound onto the tube under tension — max. operating temperature ~150°C.
Extruded Fin (Bimetallic)
Fin extruded from an aluminum outer tube bonded to the liner tube — max. operating temperature ~300°C.
Embedded / G-Fin
Fin wound into a machined groove and tightly bonded by rolling — max. operating temperature ~400°C.
KL / KLM Footed Fin
Knurled L-foot construction for improved fin-to-tube contact and mechanical bond.
LL-Foot Fin
Overlapped double L-foot wrap for added mechanical grip and heat-transfer contact area.
Bare Tube
Unfinned tube bundles for low-duty or non-fouling cooling & condensing service.
Every component engineered for continuous field duty
Finned Tube Bundles
Carbon steel, stainless, duplex, super duplex & titanium tubes with aluminum or galvanized steel fins.
Axial Fans & Fan Rings
Low-noise axial fans in aluminum, reinforced nylon, or polypropylene, sized to duty and site conditions.
Drive Systems
Belt, gear, or direct-drive arrangements with TEFC or variable-speed motors for capacity modulation.
Structural Steel Bay
Fabricated support structure carrying the bundle, fans, and plenum, with walkways and access ladders.
Plenum Chambers
Transition ductwork between fan and bundle that ensures uniform air distribution across the face area.
Louvers & Dampers
Adjustable louvers for process temperature control in varying ambient conditions.
Header Boxes
Plug, cover-plate, bonnet, manifold, or pipe headers fabricated to the specified design pressure.
Vibration & Bearing Monitoring
Vibration switches, bearing temperature detectors, and instrumentation for condition monitoring.
Maintenance Platforms
Access platforms and ladders positioned for fan, motor, and header maintenance without process shutdown.
Capability at a glance
Every bundle documented before it leaves the shop
Non-destructive examination, pressure testing, and a mechanical running test verify every unit against design intent.
Ultrasonic & Radiographic Testing
UT and RT weld examination on headers and pressure-retaining joints per code requirements.
Magnetic & Penetrant Testing
MT and PT surface examination confirming weld and material integrity before hydrostatic test.
Running & Vibration Test
Mechanical running test of the fan and drive assembly, including noise and vibration checks, prior to dispatch.
Where our air cooled heat exchangers go to work
Gas Compression & Gas Processing
Inter-stage & after-cooling for reciprocating and centrifugal compressor packages, gas gathering & gas plants.
Refining & Petrochemical
Process coolers, condensers, and overhead condensing service across refinery and petrochemical units.
Power & Turbine Lube Oil
Steam condensers, turbine lube oil coolers, and closed-circuit water cooling for power generation.