Fabrication Services — Vessel Fabrication
3-Phase Separators
Horizontal three-phase separators engineered to split well effluent into oil, gas, and water streams — with weir and interface-level control internals sized for stable oil-water disengagement.
Splitting three phases means controlling one boundary the whole time
A 3-phase separator does everything a 2-phase separator does — inlet momentum reduction, gravity settling, and mist elimination — then adds a second liquid-liquid separation stage to split the oil and water phases from each other. That second stage lives or dies on one thing: stable control of the oil-water interface level. A weir, bucket-and-weir, or interface-level controller keeps that boundary where the design intends it, so oil doesn’t carry into the water leg and water doesn’t carry into the oil outlet.
Fintelius engineers every 3-phase separator around the full retention-time picture — gas residence, oil residence, and water residence sized independently — then selects weir geometry and interface instrumentation to hold a stable boundary across the full range of expected water cut.
- Horizontal configuration, sized for simultaneous oil, water & gas disengagement
- Inlet diverter, coalescing internals, weir or bucket-and-weir oil-water control
- Interface level control (displacer or capacitance) driving automated dump valves
- Corrosion-resistant, H₂S-safe construction for sour, high-water-cut production streams
From process data to a commissioned three-phase vessel
Every separator follows the same disciplined path through the shop, whatever its weir configuration.
Process Sizing
Gas, oil & water rates and expected water cut are used to size gas capacity and independent oil/water retention time.
Weir Configuration Selection
Weir, bucket-and-weir, or interface-controller design is selected to match expected water cut variability and turndown.
Shell & Internals Fabrication
Shell is rolled and fitted with the inlet diverter, weir plates, coalescing internals, and mist eliminator.
Welding, NDE & PWHT
Welds are radiographed and ultrasonically tested; thick-walled sections undergo post-weld heat treatment.
Hydrostatic Testing & Dispatch
The complete vessel is hydrostatically tested, coated, and prepared for shipment as a skid or standalone unit.
How the oil-water boundary is held in place
Weir-Type Separator
Oil spills over a fixed overflow weir once it reaches a set level, while water is drawn from beneath — simple and robust for stable, low-variability water cuts.
Bucket-and-Weir Separator
Adds an oil bucket ahead of the weir to buffer surges and protect against slugs of water carrying into the oil outlet — preferred where water cut fluctuates.
Interface-Level-Controlled Separator
A displacer or capacitance-type interface level controller signals automated dump valves directly — no fixed weir, so the boundary can be actively held across a wide water-cut range.
Four stages, from bulk momentum to a controlled liquid-liquid boundary
Each internal component does one job in the sequence — skipping a stage compromises everything downstream of it.
Inlet Diverter
Breaks incoming fluid momentum and initiates gas release by disrupting surface tension at the point of entry.
Gravity Settling & Coalescing Section
Provides residence time and, where fitted, coalescing plates to accelerate oil droplet growth and water settling.
Weir Plate / Oil Bucket
Physically separates the oil and water compartments, holding a controlled interface level between the two liquid phases.
Interface Level Instrumentation
Displacer or capacitance-type instruments continuously monitor the oil-water boundary and signal dump valves to maintain it.
Mist Eliminator
Wire mesh or vane-pack demister removes entrained liquid from the gas phase before it exits the vessel.
Straight-Run Inlet Piping
Adequate upstream straight-run piping allows flow to develop uniformly before entering the separator, reducing turbulence-driven upsets.
What stable three-phase separation demands
Shell & Head Fabrication
Plate rolling and head forming to the design diameter, length, and wall thickness set by combined gas and dual-liquid retention sizing.
Weir & Baffle Installation
Weir plates, oil buckets, and splash baffles fitted and leveled inside the shell to the process design elevation.
Nozzle & Instrumentation Fabrication
Inlet, gas outlet, oil outlet, water outlet, relief, drain, and instrumentation nozzles with reinforcement pads.
Automated Dump Valve Integration
Level-controlled dump valves on both oil and water outlets, tied to interface and level instrumentation.
Sour Service & CRA Construction
Corrosion-resistant alloy cladding and H₂S-safe design for sour, high-water-cut production streams.
Post-Weld Heat Treatment
Stress-relief heat treatment for thick-walled shell and head sections per code requirements.
Radiography & Ultrasonic NDE
Weld integrity verification across all shell and nozzle welds before hydrostatic test.
Adjustable Flow Metering & Sampling
Adjustable metering across variable flow rates and surface sampling points for produced-fluid quality checks.
Skid Mounting & Portability
Skid-mounted, field-portable configurations for well testing and frac flowback service.
Capability at a glance
Where our 3-phase separators go to work
Oil & Gas Production
Primary separation of wellhead effluent into sales-quality oil, gas, and produced water streams.
Well Testing
Portable three-phase separators supporting well-test measurement of oil, gas & water rates for reservoir evaluation.
Frac Flowback
Handling variable, high-water-cut flowback streams following hydraulic fracturing operations.
Gathering & Central Processing
Bulk separation at central gathering facilities ahead of oil treating, water disposal & gas processing.
Sour Service Production
H₂S-safe construction protecting personnel and equipment in corrosive, sour-service production streams.
Environmental Compliance
Controlled produced-water separation supporting environmental discharge and disposal requirements.