Industrial Chillers
Engineered air-cooled and water-cooled chiller packages, sized and built on 25 years of heat transfer equipment expertise, to hold precise process temperatures under the toughest continuous industrial duty.
Process cooling, engineered around your load
An industrial chiller removes heat from a process fluid — water or a water/glycol mixture — and rejects that heat to the atmosphere, so that closed-loop cooling water can be recirculated to injection molding machines, reactors, heat exchangers, laser and welding equipment, data center CRAC/CRAH units, and other process loads at a controlled, repeatable temperature. Unlike comfort-cooling HVAC systems sized for a building’s peak day, industrial process chillers are sized and built for continuous, often 24/7 duty against a fixed thermal load, with far tighter setpoint tolerances and much higher reliability expectations.
Fintelius engineers and fabricates complete chiller packages — air-cooled and water-cooled, scroll, screw, and centrifugal compressor technology — sized to the client’s actual process duty, ambient design conditions, and site utilities, then integrates the unit with the piping, controls, and instrumentation package it will operate alongside in the field.
- Capacity range from 1 TR (3.5 kW) to 500+ TR (1,750+ kW) per unit, single or multi-compressor
- Air-cooled and water-cooled configurations, scroll, screw & centrifugal compressors
- Process leaving-water temperatures from as low as -50°C (glycol systems) to +25°C
- PLC/microprocessor control with remote monitoring & building automation integration
The vapor-compression refrigeration cycle
Every mechanical chiller — air-cooled or water-cooled — runs the same basic refrigeration cycle. The difference is only in how and where the heat is finally rejected to the environment.
Heat Absorption
Warm process water returns to the evaporator, where low-pressure liquid refrigerant absorbs heat and boils into a low-pressure vapor, chilling the water in the process.
Compression
The compressor (scroll, screw, reciprocating, or centrifugal) draws in the low-pressure refrigerant vapor and compresses it into a high-pressure, high-temperature gas.
Heat Rejection
The hot, high-pressure gas passes through the condenser. In air-cooled units, fans force ambient air across finned coils; in water-cooled units, condenser water carries the heat to an external cooling tower.
Expansion
The now-liquid, high-pressure refrigerant passes through an expansion valve, which drops its pressure and temperature before it re-enters the evaporator.
Chilled Water Delivery
Cooled process water is pumped out to the connected process loads, and the cycle repeats continuously to hold the setpoint temperature.
Compressor technology, matched to the load
Compressor selection drives capacity range, part-load efficiency, and maintenance profile — Fintelius specifies the technology that fits the actual duty cycle, not a one-size package.
Reciprocating Compressor Chillers
Piston-driven compressors well suited to smaller, variable-load facilities; typical capacity range of roughly 2–200 tons with proven reliability and simple field service.
Scroll Compressor Chillers
Two interleaving spiral scrolls compress refrigerant with fewer moving parts, low vibration, and strong part-load efficiency; typically staged in modules from 5–150 tons.
Screw Compressor Chillers
Twin helical rotors deliver continuous, high-efficiency compression for demanding duty cycles; capacities typically span 20–450 tons, extending to 400+ tons in heavy industrial packages.
Centrifugal Compressor Chillers
High-speed impellers, including magnetic-bearing, oil-free designs, give a compact footprint at large capacity, generally starting around 150 tons and scaling into the thousands of tons.
Absorption Chillers
Thermally driven cycles that use waste heat, steam, or hot water instead of mechanical compression — well suited where low-cost heat is available and electrical load must be minimized.
Air-Cooled Packages
Self-contained units rejecting heat directly to ambient air through condenser fans — no cooling tower, no process water treatment, faster installation, smaller plant footprint.
Water-Cooled Packages
Condenser water circulates to an external cooling tower, giving higher efficiency and more stable performance across ambient swings, at the cost of tower maintenance and water treatment.
Modular & Multi-Compressor Units
Multiple independent refrigeration circuits within a single package provide built-in redundancy and staged capacity control to match part-load conditions.
Low-Temperature & Glycol Systems
Purpose-built circuits handling water/glycol mixtures for process duties down to -50°C, used in chemical, pharmaceutical, and specialty processing applications.
What goes into a chiller package
Compressor
The core of the refrigeration cycle, available in hermetic (sealed) or open-drive configurations depending on serviceability requirements and duty.
Condenser
Copper-tube, aluminum-fin coils (air-cooled) or shell-and-tube bundles (water-cooled) that reject compressed refrigerant heat to air or condenser water.
Evaporator
Shell-and-tube, plate, or tank-coil heat exchanger where refrigerant absorbs heat from the circulating process water.
Thermostatic Expansion Valve
Meters refrigerant flow into the evaporator to match the actual cooling load, maintaining efficient superheat control.
Filter Drier
Removes moisture and particulate from the refrigerant circuit to protect the compressor and expansion device from contamination damage.
Condenser Fans / Cooling Tower Interface
Variable-speed fans on air-cooled units, or a tower water interface on water-cooled units, matched to the design ambient wet/dry-bulb conditions.
Microprocessor / PLC Controller
Automates compressor staging, safety interlocks, and setpoint control, with graphic display, trending, and BAS/SCADA communication.
Safety & Protection Devices
High/low-pressure switches, anti-freeze protection, overload relays, and flow switches guard the refrigeration circuit and pump set.
Chilled Water Pump Set
Primary (and secondary, where required) pumps sized to the process flow rate and system head, often supplied as an integrated skid.
Choosing the right heat-rejection path
The single biggest chiller decision is how the unit rejects heat — each path carries different trade-offs in efficiency, footprint, water use, and long-term operating cost.
Getting the specification right
Correct chiller sizing is driven by more than peak cooling load. Fintelius’s engineering team accounts for the full set of conditions the unit will actually operate under, so the package delivers rated capacity in the field, not just on a datasheet.
- Peak and part-load thermal duty, including duty-cycle and simultaneous-use factors
- Site ambient design temperature and altitude derating for air-cooled units
- Required leaving-water temperature and allowable approach/temperature differential
- Refrigerant selection (R-134a, R-407C, R-404A, R-410A, R-22 legacy retrofits, and low-GWP options such as R-1234ze)
- Redundancy requirements — N+1 compressor circuits for critical process or data center loads
- Noise limits, available footprint, and electrical supply (typically 415V ±10%, 50 Hz, 3-phase)
Representative package data
Where Fintelius chillers go to work
Oil & Gas Process Cooling
Glycol and process water cooling for gas processing, compression, and treatment facilities.
Data Centers
Precision, high-reliability chilled water for CRAC/CRAH units and liquid cooling loops, with N+1 redundancy.
Petrochemical & Power
Continuous-duty process cooling for reactors, compressors, and heat exchangers in petrochemical and power plants.
Pharmaceutical Manufacturing
Tight-tolerance temperature control for reaction vessels, cleanroom air handling, and formulation processes.
Plastics & Injection Molding
Mold and barrel cooling for injection molding, extrusion, and blow-molding operations.
Metal Processing & Laser Cutting
Process cooling for laser cutting, welding, electroplating, and die-casting equipment.